BDR-M2 |
|
|
| TOR 3415-006-22136119-2004 |
|
Simultaneous electrochemical corrosion protection of up to four galvanically isolated underground metal constructions. Functions in conjunction with cathodic protection stations.
|
|
|
|
|
|
|
| |
- Compliance with the GOST R 51164-98 "Main steel pipelines. General requirements to corrosion protection".
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
The units tolerate constant maximum current flow at electrical resistance of channels no more than 0,2 Om.
|
|
|
|
|
|
| |
- Expanded units' nomenclature.
- Electrical impedance of the channels is increased up to 0,4 Om.
- Number of control steps in the channels is increased up to 20.
- Protection current in each channel is set by one contactor.
- Possibility of multichannel blocks channels parallel connection for summed nominal and maximum current increment.
- Possibility of multichannel blocks channels series connection for channels' summed electrical resistance increment.
- Nonpolarized channels and channels of reverse current conductance can be created.
- Effective protection against atmospheric (lightning) overvoltage.
- Different blocks modifications (I, TI, AI) with the building amperemeter for direct measurement of protection currents, running through the channels to the constructions.
- Possibility of connection to systems of remote control (modifications T, TI) for measurement of:
- protection currents, running thorough the channels to the constructions;
- protection potentials on the constructions.
- Different blocks modifications (A, AI) with the channels of "forward" conduction for the following functions:
- as a polarized drainage;
- for connection of multijoint anodic earths and equalization of currents from separate rungs.
- Variants of blocks installation:
- on a flat horizontal base;
- on a flat vertical base;
- on cathodic protection test stations (KIP)
- on power transmission towers.
- Exploitation outdoors and indoors.
- Steady operation in different climatic zones at wide ambient temperature range - from -45°C up to +45°C
- Long-life performance - up to 20 years.
|
|
|
|
|
|
| |
| Model |
Number of channels |
Notes |
| BDR-M2-15/25-1-U1 |
single-channel |
|
| BDR-M2-15/25-2-U1 |
two-channel |
| BDR-M2-15/25-3-U1 |
three-channel |
| BDR-M2-15/25-4-U1 |
four-channel |
|
|
|
|
|
|
| |
| # |
Model |
Characteristics |
| 1 |
BDR-M2-15/25-1(T,I,TI)-U1 BDR-M2-15/25-2(T,I,TI)-U1 BDR-M2-15/25-3(T,I,TI)-U1 BDR-M2-15/25-4(T,I,TI)-U1 |
The units provide current flow from the "Input" binder to the "Output" binders, at negative voltage supply to the "Input" binder. |
|
|
|
|