Cathodic protection module «ENERGOMERA»

 
Cathodic protection module «ENERGOMERA» - MKZ-M12

MKZ-M12

TOR 3415-019-22136119-2005
Efficient protection of metal substructures in high corrosion hazard zones with 100% back-up in circuits supplying protected structure (pipeline) with cathodic current.
 
  Standard compliance
 
  • Complies with the GOST R 51164-98 and GOST 9.602-89
  • Cathodic protection module MKZ-M12 has Certificate of compliance with State Standard Committee of Russia N ROSS.RU.AJu11.N00309, issued by Organization on certification «VNIIGAZ-CERTIFICATE».
  Specifications
 
MKZ-M12 module types Rated output current, A Rated output voltage, V Remarks
MKZ-M12-15-24-U2 15 24 No inbuilt electric energy meters and circuit breakers at supply main infeeds
MKZ-M12-20-30-U2 20 30
MKZ-M12-32-30-U2 20 30
MKZ-M12-25-48-U2 20 30
MKZ-M12-32-48-U2 20 30
MKZ-M12-42-48-U2 20 30
MKZ-M12-SE-15-24-U2 20 30 With inbuilt electric energy meters and circuit breakers at supply main infeeds
MKZ-M12-SE-20-30-U2 20 30
MKZ-M12-SE-32-30-U2 20 30
MKZ-M12-SE-25-48-U2 20 30
MKZ-M12-SE-32-48-U2 20 30
MKZ-M12-SE-42-48-U2 20 30

- teleautomatic system coupler is not installed in A line module;
- AS-1-U2 type signal adapter is installed in B line modules for connection with teleautomatic systems: «Magistral-2»; «STN-3000», «UNK-TM» and other;
- AS-2-U2 type signal adapter is installed in V line modules for connection with teleautomatic systems: «SupeRTU-4»;
- AS-3-U2 type signal adapter is installed in G line modules for connection with teleautomatic systems: «ELSI-2000», «ELSI-T».

The specifications of the modules correspond to the technical conditions of the applied submachines:
  Design features
 
  • CP modules MKZ-M12 have climatic modification U2.
  • The modules MKZ-M12…-U2 have modifications without electricity meter.
  • The modules MKZ-M12-SE…-U2 have modifications with electricity meter.
  • Level of protection against contact with current-carrying parts and against environmental attacks: for the modules - IP01, and for the built-in electronic component - IP44 (according to GOST 14254-96 (Sealing protection level (IP)).
  • The modules can be linked up to different telemechanic systems for remote control of:
    • values of measured potentials difference, output current, output voltage;
    • occurrence\absence of supply mains voltage;
    • accumulative metering of input electric energy (only for MKZ-M12-SE);
    • protection potential remote setting;
    • protection current remote setting;
    • output voltage remote setting;
    • converter remote restarting;
    • converter remote switching-out\switching-on;
    • remote control of the switched on converter.
  • The modules are adapted to the following telemechanic systems: «UNK-TM», «Magistral-2», «STN-3000», «SupeRTU-4», «SKAT», «ELSI-2000», «ELSI-T», «TELUR».
  • The modules provide uninterrupted work without routine maintenance and repairs for no less than 6 months.
  • The modules provide the option of operation from one or two feeds of supply mains.
  Modules provide
 
  • Possibility of energy supply from two different supply main feeders: the main and back-up (energy supply class – 1, according to Electrical Safety Rules).
  • High accuracy of protection potential maintenance - up to ±0,5% and protection current maintenance - up to ±1% (in automatic operating mode).
  • Set electric parameters at supply mains voltage variation from 176V to 242V and operability at supply mains voltage variation from 160V up to 250V.
  • Automatic switching-out of the main converter (at main feeder supply voltage failure) and switching-on of the back-up converter.
  • Automatic switching-out of the main converter (at output voltage absence in main converter output) and switching-on of the back-up converter.
  • Automatic switching-out of the main converter (at main feeder supply voltage occurrence) and switching-out of the back-up converter.
  • Automatic switching-out of the back-up converter (if back-up feeder supply voltage value overruns the set limits).
  • Automatic switching-on of the back-up converter (at back-up feeder supply voltage occurrence).
  • Compliance with the GOST 9.602-89 "Underground installations. General requirements to anti-corrosion protection".
  • Automatic return to a present mode when energized after power supply failures.
  • Steady operation during load-off and load-on.
  • Effective lightning surge protection of load and supply voltage inlets.
  • Possibility of nominal rated voltage step increasing up to 2Unom at peak output current 0,5Inom.
  • Control of output voltage, protection current and protection potential by the built-in measuring devices.
  • Electrical and fire safety due to the usage of a circuit breaker at the CP module's input, which automatically disconnects the converter from the supply mains in case of its breakage;
  • Low level of radio noise conforming to the requirements of GOST R 51522-99 (IEC 61326-1-97).
  • Availability of time counter for tracking of module energization and manual-on position time.
  Operating modes
  The modules can operate in one of three modes:
  • automatic maintenance of measured potential difference at the preset level, within the limits from -0,5V up to -3,5V;
  • automatic stabilization and maintenance of protection current at the preset level;
  • manual setting of output voltage.