VOLTAGE TRANSDUCER “ENERGOMERA”

 
VOLTAGE TRANSDUCER “ENERGOMERA” - PN-OPE-M11

PN-OPE-M11

TOR 3415-011-22136119-2007
Automatic transducers PN-OPE-Ì11 are intended for effective protection from electrochemical (soil) corrosion of underground metal constructions, communications, pipelines, petrochemicals warehouses, supporting fittings and other similar objects in terms of corrosive soil influence including unfavorable effect of stray current. Transducers are indented for outdoor instillation (installation category – 1).
 
  Standard compliance
 
  • Comply with GOST R 51164-98 «Main steel pipelines. General requirements to anticorrosion protection».
  • Comply with GOST R 9.602-2006 «Underground constructions. General requirements to anticorrosion protection».
  • Produced according to the manufacturer’s terms of reference: TOR 3415-011-22136119-2007.
  • Certified: certificate of conformity N POCC.RU.ME86.H00391. Comply with GOST.
  Application field
  Oil, gas, chemical, power and other industries with disposal pipeline networks of different purpose: gas, oil, products pipelines, municipal facilities objects, other underground metal lines and constructions including those which are situated in the zone of D/C electrified rail transport (railroads, tramways, etc). Various organizations having underground metal communications and constructions in the soils with high corrosion activity.
  Specifications
 
Items Norm for transducers types
PN-OPE-M11-C1 (C0, C3)
15-24-U1 20-30-U1 32-30-U1 25-48-U1 32-48-U1 42-48-U1
Supply main voltage, V 220 (+22/-44)
Supply main frequency, Hz 50±1
Nominal output active power, kW 0,35 0,6 1,0 1,2 1,5 2,0
Nominal output current, A 15/7,5 20/10 32/16 25/12,5 32/16 42/21
Nominal output voltage, V 24/48 30/60 30/60 48/96 48/96 48/96
Active consumed power, not more than, kW

0,450


0,732


1,143


1,412


1,765


2,290
Full consumed power, not more than, kWA

0,459


0,747


1,166


1,440


1,800


2,337
Efficiency output, not less than, %

80


82


84


85


87


88
Power factor, not less than

0,98
Output voltage regulation range, not less than, %

5-100
Output current regulation range, not less than, %

5-100
Protection current maintenance accuracy, % ±1
Protection potential maintenance accuracy, %

±0,5
Transducers weight without interface block (with interface block), not more than, kg 68 (70) 70 (72) 73 (75)
Overall dimensions (length x depth x height), mm 600 x 400 x 800
Service life, years 12
  Notes
 
  • PN-OPE-M11-C1 transducers contain inbuilt single phase electricity meter;
  • PN-OPE-M11-C0 transducers do not contain inbuilt electricity meter;
  • PN-OPE-M11-C3 transducers contain inbuilt multitariff electricity meter.
  Design features
 
  • Degree of protection against contact with conducting parts and environmental influence – IP34 according to GOST 14254.
  • Electric shock protection class – 1 according to GOST 12.2.007.0.
  • Comply with fire-safety requirements according to GOST 12.1.004.
  • Cases of all modifications have similar unified construction, overall and conjunctive dimensions.
  • Metal case provides advanced protection against mechanical damage.
  • Polymeric powder coating of light tones is resistant to environmental and mechanical influence, this increases case corrosion resistance and reduces solar radiation heat.
  • Service life – up to 12 years (up to 100 000 hours).
  Reliability characteristics
 
  • Warranty period:
    - 2 years from putting into operation;
    - .5 years from delivery (shipping).
  • Warranty period for transducers supplied to JSC "Transneft":
    - 2.5 years from putting into operation;
    - 3 years from delivery (shipping).
  Functional capabilities
 
  • Transducers operate in any selected mode:
    – protection potential automatic maintenance at the preset level;
    – protection current automatic stabilization and maintenance at the preset level;
    – output voltage and protection current manual setting;
    – periodical load current interruption by external control signal from supervisory system for polarization potential measurement on the construction.
  • Convertors provide:
    – high accuracy of protection potential maintenance – up to ±0.5% and protection current – up to ±1% (in automatic operating mode);
    – set electric parameters at supply main voltage measurement from 176 V to 242 V;
    – smooth shift to set output voltage and load current values when energized, also at voltage fallouts and further mains voltage appearance;
    – load current pulsation factor less than 3% according to GOST R 51164-98;
    – transducers running time record;
    – load current limitation at overload and short-circuit in load circuit;
    – long trouble-free operation in the off-load mode, at the breakdown of the cable leading to the construction or anodic grounding;
    – steady operation at load resistance changes from 0.2 up to 5.0 of the nominal value (25 times!);
    – possibility of prompt switching to double nominal voltage mode (2 Unom) at half load current (0.5 Inom);
    – low energy consumption due to high energy data: efficiency output and cos;
    – low radio noise level as required by GOST R 51522-99. – load current pulsation factor.
  MAINTENANCE CONDITIONS
 
  • ambient air temperature range: from – 40°C to + 45°C;
  • relative humidity: up to 98% (at 25°C);
  • atmosphere pressure (86.6 – 106.7) kPa (from 650 to 800 mm hg);
  • I, II types atmosphere;
  • open air installation (installation category – 1).
  COMBINED ACTION WITH SUPERVISORY SYSTEMS
 
    Transducers are adjusted to main supervisory systems applied at the following establishments:
    JSC «GASPROM», JSC «Transneft», JSC «Transnefteprodukt», regional gas-distributing organizations (GDO): «UNK – TM», «Magistral – 2», «STN – 3000», «SupeRTU - 4», «SKAT», «ELSI – 2000», «TELUR» and others.
    Transducers provide remote control of:
    - output voltage and current, protection potential;
    - protection potential remote installation (in automatic mode – “AUT”);
    - protection current remote installation (in automatic mode – “CUR”);
    - output voltage remote installation (in manual mode – “MAN”);
    - switching the convertor on and off;
    - output current periodical interruption;
    - unauthorized access inside the convertor.
  Designation structure
  PN-OPE-M11-CX-XX-XX-U1-X-XXX
interface type of connection with supervisory system (in the presence of interface block): 4.20, 485;
convertors line designation;
climatic modification and installation category according
to GOST 15150-69;
nominal output voltage, V;
nominal output current, A;
presence of electricity meter and rate quantity;
modification code;
input current nature: single-phase;
output current nature: constant;
cooling: natural;
voltage convertor;
  Overall dimensions
  PN-OPE-M11 - VOLTAGE TRANSDUCER “ENERGOMERA”