PRODUCTS CONTACTS SERVICE
add favorite JSC "Concern Energomera"Sate mapconcern@energomera.runews@energomera.ru
 RU  |  PL
ABOUT COMPANY INVESTORS TRAINING EXHIBITIONS & SEMINARS SERVICE PRODUCTS

» Electrochemical protection equipment

» New products

» Culvert Electrochemical Protection Equipment

» V-OPE-M1

» V-OPE-M2

» V-OPE-M3

» V-OPE-M5

» V-OPE-M6

» V-OPE-M7

» V-OPE-M4

» Cathodic Protection Transformers and Modules

» Electric Drainage

» Accessories

.: ENERGOMERA TM
    PRODUCTS

» Electricity meters

» Automatic Meter Reading Systems

» Switchboards

» Low Voltage Products

» Telecommunication cabinets

» Verification (Calibration) sets

 

Automated cathodic protection (CP) station with manual control «Energomera»

 
Automated cathodic protection (CP) station with manual control «Energomera» - V-OPE-M4

V-OPE-M4

TOR 3415-007-22136119-2000
Simple and fail-safe rectifier providing manual step-by-step control of output voltage and protection current.
 
  Standard compliance
 
  • Compliance with the GOST 9.602-89 «Underground constructions. General requirements to corrosion protection».
  Application field
  Oil, gas, chemistry, energy and other industrial complexes that have not cross-country pipeline network (gas lines, oil-pipe lines, product pipes and other), storage-tanks, other metal substructures. Public utility facilities supporting locality communications (water pipelines, power and information cables with metal sheaths and other).
Electrified railway authorities, municipal streetcar and underground services.
Different organizations that have metal substructures in soils with high corrosion activity.
  Specifications
 
Items Parameter value for V-OPE-M4 (M4.1*)
25-24-U1 25-24-U1 42-24-U1 42-48-U1 63-48-U1
Supply main voltage, V 220 (+22/-44)
Supply main frequency, Hz 50±3
Nominal output power, kW 0,35 0,6 1,0 2,0 3,0
Nominal output current, A 15 25 42 42 63
Nominal output voltage, V 24 48
Total power consumption, not more than, kW 0,52 0,9 1,49 2,98 4,46
Efficiency, in the nominal mode, not less than, % 70
Power factor, in the nominal mode, not less than 0,96
Number of phases 1
Output current regulation range, not less than, % 5-100
Control step, V 1,0 2,0
Overall dimensions, mm 600x400x800
Weight, not more than, kg 70 74 80 94 98
Technological lifespan, not less than, hours 100000
Service life, not less than, years 20
* rectifier V-OPE-M4.1 is produced without inbuilt electric energy meter.
  Design features
 
  • CP stations have climatic modification - U, installation category - 1 and are designed for placement on open air.
  • Maintenance-free period of CP stations - no less than 6 months.
  • The rectifier is adapted to the main teleautomatic systems that are applied at JSC «GASPROM», JSC SC «TRANSOIL», JSC SC «TRANSOILPRODUCT» industries, regional gas-distribution organizations (GDO): «UNK-TM», «Magistral-2», «STN-3000», «SupeRTU4», «SKAT», «ELSI-2000» («ELSI-T»), «TELUR».
  • The rectifier has low radio interference level not influencing other electric devices, communications, radio- and television broadcast that allows using it in community residential sectors.
  • Steady operation in different climatic zones with ambient temperature range: from -45°C up to +45°C.
  • Expansion of useful operating life up to 100000 hours, and service life - till 20 years.
  Rectifiers provide
 
  • Automatic return to a present mode when energized after power supply failures.
  • Steady operation during load droppings and surges.
  • Effective overload and short circuit protection of load circuits.
  • Effective lightning surge protection of load and supply voltage inlets.
  • Circulating current drainage from the protected metalware to the anodic grounding electrode at the absence of mains supply voltage.
  • Low power consumption due to high energy data and accumulating electric energy metering by a build-in meter.
  • Electric safety of the maintenance staff provided by the earth leakage circuit breakers (UZO), automatically disconnecting CP stations from power line at a casual touch to current carrying circuits.
  • Control of output voltage and load current by build-in measuring devices.
  • Metering of time of energization and manual-on position of CP station.
  Operating modes
 
  • Rectifiers operate in the mode of manual output voltage and protection current regulation.