PRODUCTS CONTACTS SERVICE
add favorite JSC "Concern Energomera"Sate mapconcern@energomera.runews@energomera.ru
 RU  |  PL
ABOUT COMPANY INVESTORS TRAINING EXHIBITIONS & SEMINARS SERVICE PRODUCTS

» Electricity meters

» CE line meters

» Three-phase

» CE6803V

» CE6803V-R32

» CE6803V-R31

» CE6803V-S33

» CE6803VS

» CE6804

» Multifunctional

» Assembly

.: ENERGOMERA TM
    PRODUCTS

» Automatic Meter Reading Systems

» Switchboards

» Low Voltage Products

» Telecommunication cabinets

» Verification (Calibration) sets

» Electrochemical Protection Equipment

 

three-phase electricity meter

 
three-phase electricity meter - CE6803V case modification – R32

CE6803V

case modification – R32
TOR 4228-010-04697185-97
Intended for single-tariff energy measurement and metering.
Accuracy class: 1; 2.
New R32 case – for board and TN35 DIN-rail mounting.
Complies with all the DIN-rail mounting standards.
Possibility of installation in switchboard equipment together with any kind of switching equipment according to DIN standards.
 
  Standard compliance
 
  • Complies with GOST R 52320-2005 (IEC 62052-11:2003)
  • Complies with GOST R 52322-2005 (IEC 62052-11:2003)
  Specifications
 
Items Values
Accuracy class 1; 2
Tariff quantity 1
Measuring network frequency, Hz 50±2.5 (60±3)
Rated phase (linear) voltage*, V 57.7; 100; 127; 220;
Rated current strength*, A 1; 5; 10
Maximum current strength*, A:
- for directly connected meters
- for transformer-connected meters

50; 100
7.5
Starting current (sensitivity):**
- for directly connected meters, Ib
- for transformer-connected meters, Inom

0.004; 0.005
0.002; 0.003
Full power consumed by the parallel circuit, not more than, V*A, (W)

6(0.6)
Full power consumed by the series circuit, íå áîëåå, V*A 0.1
Operating temperature range, °Ñ from -40 up to 60
Overall dimensions, mm 143 x 170 x 52
Weight, not more than, kg 1

* - depending on the modification, see meter designation structure
** - depending on the accuracy class
  Reliability characteristics
 
  • Mean time to failure — 160000 hours.
  • Calibration interval — 16 years.
  • Average service life — 30 years.
  • Warranty period — 4 years (including storage period).
  Overall dimensions
  CE6803V - Three-phase electricity meter
  Designation structure
  CE6803V X X X X X X X
Case type:
R32 - for board and DIN-rail mounting
Register type:
M7 - seven-bit electromechanical;
M6 - six-bit electromechanical
Connection diagrams:
3ph.4w. - for three-phase four-wire meters;
3ph.3w. - - for three-phase three-wire meters
Rated (basic) and maximum current:
1 - 1.5 A;
1 - 7.5 A;
5 - 7.5 A;
5 - 50 A;
10 - 100 A
Rated phase voltage for four-wire meters and linear voltage for three-wire meters:
57.7 V; 127 V; 220 V - for four-wire meters;
100 V - for three-wire meters
Tariff quantity:
"1T" - single-tariff meter;
Accuracy class according to GOST R 52322-2005
1
2
  Documentation
 
  Operating manual PDF 406 kB
Go top
ABOUT COMPANY NEWS TRAINING PUBLICATIONS IN MASS MEDIA SERVICE PRODUCTS
© 2001-2010 Concern Energomera JSC