SINGLE-PHASE MICROPROCESSOR
MULTIRATE ELECTRICITY METER
|
|
|
|
| |
 |
CE6827M1 |
|
|
| TOR 4228-043-46146329-2004 |
Electric energy measurement and metering, three tariffs, twelve time zones.
Accuracy class: 1.0; 2.0
Nominal voltage: 220 V
Nominal current: 5 A; 10 A
Telemetric channels
Digital interface RS485
Power metering in half-hour intervals;
Combining 255 meters into one subsystem (by interface RS485);
Keeps indication in case of supply voltage absence.
|
|
|
|
|
|
|
| |
- IEC 1036-90 (GOST 30207) compliant
- The meter is certified and listed in the Russian Federation and the CIS State Register of Measurement Facilities
|
|
|
|
|
|
| |
* - depending on modification, see the designation structure.
|
|
|
|
|
|
| |
- LCD - with wide operating temperature range
- Measurement accuracy technological allowance
- Resistance to environmental, mechanical and electromagnetic influence
- Low energy consumption
- Standard telemetric output
- Digital interface RS485
- Tamper protection
- The meter operation light indicator
|
|
|
|
| |
Reliability characteristics |
|
|
|
| |
- Mean time to first failure - 160000 hours
- Verification interval - 8 years
- Average service life - 24 years
- Warranty period - 3 years
|
|
|
|
|
|
| |
- Consumed electric energy metering and indication with progressive total under three tariffs and per tariff.
- Consumed electric energy metering with progressive total, at the beginning of the current and eleven previous months.
- Indication of current time.
- Indication of current date.
- Setting of up to 12 month tariff programs, separately for the workdays, weekends (holidays), up to 36 programs in total.
- The meter provides transmission via interface:
- minute and half-hour power values;
- up to 1488 electric energy values, accumulated in half-hour intervals;
- day and month half-hour power maximums.
- Indication of current tariff.
- Automatic tariff switch.
- Day clock rate correction value setting.
- "Summer"/winter time switch (with the "winter", "summer" switch months setting).
- Clock service life and all the accumulated data storage during eight years in case of supply voltage absence.
- Accumulated data and program memory unauthorized change protection.
|
|
|
|
|
|
| |
CE6827M1 X X X X X X X
|
|
|
|
|
|
|
|
|
|
P - extra memory
|
Tariff change:
T - by inbuilt clock;
S - by external signal
|
Case type:
S1 - for board mounting
|
Interface type:
1 - EIA485
|
Nominal and max. current:
5-50 A;
10-100 A
|
Nominal voltage:
220 V
|
Accuracy class according to GOST 30207-94:
1.0;
2.0
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|