PRODUCTS CONTACTS SERVICE
add favorite JSC "Concern Energomera"Sate mapconcern@energomera.runews@energomera.ru
 RU  |  PL
ABOUT COMPANY INVESTORS TRAINING EXHIBITIONS & SEMINARS SERVICE PRODUCTS

» Verification (Calibration) sets

» Electric Energy Meter Calibrators

» ENERGOMERA CU001

» CU6800

» CU6804M

» Portable Metrological Equipment

» Standard Meters

» Accessories

.: ENERGOMERA TM
    PRODUCTS

» Electricity meters

» Automatic Meter Reading Systems

» Switchboards

» Low Voltage Products

» Telecommunication cabinets

» Electrochemical Protection Equipment

 

Automatic test station for verification of single-phase electricity meters

 
ENERGOMERA CU001 - Automatic test station for verification of single-phase electricity meters

ENERGOMERA CU001

TOR 4222-036-46146329-2003
Test station for automatic verification and adjustment of electronic and induction-type single-phase active energy meters of 1,0 accuracy class and of less precision. Provides group verification of meters with internal connection between series and parallel circuits.
 
  NORMATIVE-LEGAL SUPPORT
 
  • Compliance with the GOST 22261 "Means for measuring electrical and magnetic quantities. General specifications"
  • Certified in Russia and CIS
  SPECIFICATIONS
  Items Values
  Basis relative error at verified meters inaccuracy test, (%)
from ±0,2 or from ±0,5 (for different modifications)
  Inaccuracy of output voltage setting, %
±1,0
  Inaccuracy of output current strength setting, %
±1,0
  Output power of flagpole source in the channel of, V*A:
- voltage
- current

up to 200
up to 400
  Coefficient of nonlinear distortions of output signals, not more than %

2
  Type of supply circuit
single-phase 220V, 50Hz or 60Hz
  Power consumption, not more than, V*A
1200
  Overall dimensions, mm:
- stand (with the source of test signals)
- rack

600x550x770
1400x550x1550
  Weight, no more than, kg:
- stand
- rack

68,5
65
 
  PECULIAR FEATURES
 
  • Test station allows meters verification in manual, automatic and semi-automatic modes (inaccuracy, threshold of sensitivity, shunt running absence tests).
  • Test station allows checking of operation of meters' measuring indicators in the "dosed energy" mode and testing of correspondence of quantity of impulses of the main transmitting device to increment of the measuring indicator readings.
  • Automatic, semi-automatic and manual modes are provided by PC.
  • Adjustment range of output stabilized signal of voltage is from 100 up to 288 V, of stabilized signal of current is from 0,01 up to 120 A.
  • Output voltage circuits are protected from short circuit break, and output current circuits - from load circuit break.
  • The complete set includes PC and software of upper level.
  • The quantity of meters under simultaneous test - 6, 12 or 18, depending on modification (1, 2 or 3 racks in the set).
  • Test station modifications, which include galvanic isolation unit (suffix "R" in symbolic type), allows group verification of meters with internal connection between series and parallel circuits.
  • Availability of power factor equalizer, which almost excludes maximum harmonic in public current.
 
  RELIABILITY CHARACTERISTICS
 
  • Verification interval - 1 year.
  • Warranty - 1,5 years.
  • Service life - not less than 8 years.
 
  TEST STATION MODIFICATIONS
 
CU001/1-02-00-K     CU001/1-02-0F-K
CU001/2-02-00-K     CU001/2-02-0F-K
CU001/3-02-00-K     CU001/3-02-0F-K
CU001/1-02-R0-K     CU001/1-02-RF-K
CU001/2-02-R0-K     CU001/2-02-RF-K
CU001/3-02-R0-K     CU001/3-02-RF-K
CU001/1-05-00-K     CU001/1-05-0F-K
CU001/2-05-00-K     CU001/2-05-0F-K
CU001/3-05-00-K     CU001/3-05-0F-K
CU001/1-05-R0-K     CU001/1-05-RF-K
CU001/2-05-R0-K     CU001/2-05-RF-K
CU001/3-05-R0-K     CU001/3-05-RF-K
  DESIGNATIONS STRUCTURE
  CU001 X - X-X - X X - X
K - availability of PC
Availability of photoreading devices for control of induction-type meters disks rotation.
0 - not available
A - photoreading devices are included (at all verification places of the station)
Availability of galvanic isolation unit, which allows verification of meters with internal connection between series and parallel circuits
0 - not available
R - galvanic isolation unit is included
Numerical code of main setting error
02 - from 0,2%
05 - from 0,5 %
Number of racks (verification places)
1 - one rack (6 verification places)
2 - two racks (12 verification places)
3 - three racks (18 verification places)

Go top
ABOUT COMPANY NEWS TRAINING PUBLICATIONS IN MASS MEDIA SERVICE PRODUCTS
© 2001-2010 Concern Energomera JSC