PRODUCTS CONTACTS SERVICE
add favorite JSC "Concern Energomera"Sate mapconcern@energomera.runews@energomera.ru
 RU  |  PL
ABOUT COMPANY INVESTORS TRAINING EXHIBITIONS & SEMINARS SERVICE PRODUCTS

» Low Voltage Products

» Single-Phase RCD-VAD

» Three-Phase RCD-VAD

» Circuit Breakers

» Mini Circuit Breaker (MCB) 45-29

» Pulse Voltage Clippers

» Current limiters

.: ENERGOMERA TM
    PRODUCTS

» Electricity meters

» Automatic Meter Reading Systems

» Switchboards

» Telecommunication cabinets

» Verification (Calibration) sets

» Electrochemical Protection Equipment

 

Automatic tripping circuit breaker

 
Mini Circuit Breaker (MCB) 45-29 - Automatic tripping circuit breaker

Mini Circuit Breaker (MCB) 45-29

RMEA 656111.017 TU
– Short-circuit and overload protection
– Protection against fire and overcurrents
– Infrequent monitoring of electric circuit sections
 
  NORMATIVE-LEGAL SUPPORT
 
  • Compliance with the GOST R 51345 (Safety of machinery. Interlocking devices associated with guards. Principles for design and selection)
  SPECIFICATIONS
  Items Values
  Circuit nominal voltage, (V)
380/220
  Nominal frequency, (Hz)
50
  Number of poles
1, 2, 3, 4
  Nominal current, (A)
10; 16; 25; 32; 40; 50; 63
  Warranty, (years)
5
 
  ADVANTAGES
 
  • Has built-in overcurrents protection system, provides automatic switch-off at overload currents and short circuits. S-type characteristics of instantaneous release device (break-time at 10 In current is no more that 0,1 s).
  • Breaking differential current regulation during the operation is impossible.
  • Modifications with nominal current from 10 up to 63 A.
  • Nominal make-and-break capacity is 3000 A.
  • Withstands standard environment (type U 3.1).
 
  OVERALL, MOUNTING DIMENSIONS AND WEIGHT
 

with nominal current: 10-63 A

Mini Circuit Breaker (MCB) 45-29 - Automatic tripping circuit breaker
 
Number of poles 1 2 3 4
Width (L), mm 18 36 54 72
 
  MODIFICATIONS
  Type Nominal
current (In), A
Number
of poles
Nominal
make-and-break
capacity (Im), A
VA45-29-S10-1 10 1 3000
VA45-29-S10-2 10 2 3000
VA45-29-S10-3 10 3 3000
VA45-29-S10-4 10 4 3000
VA45-29-S16-1 16 1 3000
VA45-29-S16-2 16 2 3000
VA45-29-S16-3 16 3 3000
VA45-29-S16-4 16 4 3000
VA45-29-S25-1 25 1 3000
VA45-29-S25-2 25 2 3000
VA45-29-S25-3 25 3 3000
VA45-29-S25-4 25 4 3000
VA45-29-S32-1 32 1 3000
VA45-29-S32-2 32 2 3000
VA45-29-S32-3 32 3 3000
VA45-29-S32-4 32 4 3000
VA45-29-S40-1 40 1 3000
VA45-29-S40-2 40 2 3000
VA45-29-S40-3 40 3 3000
VA45-29-S40-4 40 4 3000
VA45-29-S50-1 50 1 3000
VA45-29-S50-2 50 2 3000
VA45-29-S50-3 50 3 3000
VA45-29-S50-4 50 4 3000
VA45-29-S63-1 63 1 3000
VA45-29-S63-2 63 2 3000
VA45-29-S63-3 63 3 3000
VA45-29-S63-4 63 4 3000

Go top
ABOUT COMPANY NEWS TRAINING PUBLICATIONS IN MASS MEDIA SERVICE PRODUCTS